MORE SPECIFICTATIONS
|
|
SPECIFICATIONS FOR SENTRY-PRO AUTOMATIC OPERATED STANDBY SETS WITH LPG OR NATURAL GAS FUELED ENGINES. MODELS SHOWN BELOW ARE ACTUALLY, THE SAME GEN-SET, BETWEEN LPG AND NAT. GAS FUEL. NAT. GAS HAS AN AVERAGE 10% TO 20% REDUCTION IN BTU CONTENT COMPARED TO LPG FUEL, THEREFORE LOWERING ENGINE HP, WHICH LOWERS KW OUTPUT. FOLLOWING ARE SPECIFICATIONS COVERING EACH MODEL WITH BOTH FUELS. |
| GENERATOR MODELS WITH SINGLE AND THREE PHASE KW/KVA RATINGS | |||||
|
1 PHASE MODELS |
SPS-100-1 | SPS-120-1 | SPH-120-1 | SPV-160-1 | |
| STANDBY KW @ 1 PHASE, 1.0 P.F. | LPG | 10.0 | 12.0 | 11.0 | 15.0 |
| NG | 8.5 | 10.0 | 9.0 | 12.5 | |
| STANDBY AMPS @ 120 VOLTS | LPG | 83 | 100 | 92 | 124 |
| NG | 75 | 84 | 75 | 104 | |
| STANDBY AMPS @ 240 VOLTS | LPG | 41 | 50 | 46 | 62 |
| NG | 37 | 42 | 37 | 52 | |
|
3 PHASE MODELS |
SPS-100-3 | SPS-120-3 | SPH-120-3 | SPV-160-3 | |
| STANDBY KW/KVA OUTPUT @ 3 PHASE, .8 P.F. | LPG | 10.0/12.5 | 12.0/15.0 | 11.0/13.5 | 15.0/18.8 |
| NG | 8.5/10.5 | 10.0/12.0 | 9.0/11.0 | 12.5/15.6 | |
| ENGINE SPECIFICATIONS | |||||
| ENGINE | SUBARU |
HONDA
|
VANGUARD | ||
| ENGINE NAMEPLATE HP | LPG | 18 | 20 | 19 | 28 |
| NG | 16 | 18 | 16 | 23 | |
| ENGINE CYL. | 2 | 2 | 2 | 3 | |
| ENGINE RPM | 2 POLE, 3600 RPM | ||||
| ENG. PISTON AREA, CU. CM. | 653 | 720 | 670 | 952 | |
| ENGINE FUEL | LPG | LPG FUEL : 6 OUNCE PRESSURE (11 INCHES WATER COLUMN), VAPOR WITHDRAWAL SYSTEM | |||
| NAT. GAS | NATURAL GAS : 4 OUNCE OR 6 OUNCE PRESSURE (7" OR 11" WATER COLUMN) | ||||
|
GENERATOR SPECIFICATIONS |
|||||
| TYPE | REVOLVING FIELD, CLC CAPACITOR REGULATION | REVOLVING FIELD | |||
| "KLEEN-POWER" | WAVEFORM DISTORTIONS AVERAGE ONLY 6% | 3% - 4% | |||
| ELECT. MOTOR START ABILITY FOR CODE G MOTORS | LPG | 2 | 3 | 5 | 6 |
| NG | 1-1/2 | 2 | 3-1/2 | 5 | |
|
CONTROL SPECIFICATIONS |
|||||
| CONTROLLER | AUTO START-STOP BY SPECIAL DIGITAL MICROPROCESSOR | ||||
| ENGINE AND GENERATOR ANNUNCIATOR MONITOR SYSTEM | MONITOR AND UATO SHUTDOWN FOR: OVERCRANK, OVERSPEED, UNDERSPEED, LOW OIL. GENERAL ANNUNCIATION FOR: LOW BATTERY, NOT IN STANDBY, HIGH TEMPERATURE, AND ENGINE RUNNING. | ||||
| METER PACKAGE | RUN TIME METER AND ANNUNCIATORS | ||||
| CIRCUIT BREAKER | STANDARD EQUIPMENT ON ALL SP SERIES GEN-SETS | ||||
| COMPLETE GENERATOR SET SPECIFICATIONS | |||||
| WEATHER HOUSING | ALL HOUSINGS ARE MADE OF "RUST-PROOFED" GALVANEEL STEEL AND SUITABLE FOR ALL WEATHER PROTECTION. AIR BAFFLES AND SOUND PROOF FOAM ALLOWS SUPERIOR SOUND DEADENING BENEFITS. | ||||
| OPEN SET DIM. LG X WI X HI | 42" X 28" X 23" | 52" X 37" X 29" | |||
| STD. HOUSED SET DIM. LG X WI X HI | 47" X 28" X 28" | 70" X 37" X 38" | |||
| S.S. HOUSED SET DIM. LG X WI X HI | 47" X 28" X 28" | 70" X 37" X 38" | |||
|
DETAIL SINGLE MODEL 4-PAGE SPECIFICATION SHEETS |
|
| SPH-120, 60 & 50 HZ, 1 & 3 PHASE | |
| SPS-120, 60 & 50 HZ, 1 & 3 PHASE | SPV-160, 60 & 50 HZ, 1 & 3 PHASE |
| ALL 60 HZ DRY-FUEL COMBO SPECIFICATION SHEET |
ALL 50 HZ DRY-FUEL COMBO SPECIFICATION SHEET |
|
TYPICAL SENTRY-PRO DRY FUEL, AUTOMATIC OPERATION When normal power fails, SENTRY-PRO automatically starts and supplies your selected emergency loads. Upon return of normal power, SENTRY-PRO automatically shuts down and returns emergency loads back to normal power. These actions require no operator to be present. All 2-pole, 3600 RPM, SPH & SPV series, 1 phase or 3 phase sets can use almost any 2-wire controlled automatic transfer switch (ATS), whether it's our model or customer's furnished 2-wire ATS
A TYPICAL "ENGINE START" ACTION IS AS FOLLOWS: A TYPICAL "ENGINE STOP" ACTION IS AS
FOLLOWS: The automatic transfer switch is included with standby generators as a "packaged" standby system, or generator is offered as a separate item, so that customer furnished ATS or other 2-wire sensing system can be used. A choice of 100 amp or 200 amp, UL-1008 certified auto transfer switch can be selected Also, view "100 & 200 Amp Automatic Transfer Switch" for specifications on both transfer switches. All air cooled, residential standby sets, at 3600 RPM, will not have SENTINEL-SCOUT These gen-sets will be automatically controlled by a digital microprocessor, giving protection for: auto start-stop upon demand of sensor signals • time delay for engine crank cycle • 3 cycle engine crank attempt before final shutdown • low oil level auto shutdown • over heat auto shut down • over speed and under speed auto shut down • low battery voltage auto shutdown • time delay for engine cooling auto shutdown after utility power is restored. A built-in LED annunciator shows the following shut-down conditions: high temperature • over crank• over speed• under speed• low oil • low battery. Also shown is: "Engine Running" (everything is normal while gen-set is in operation) and "Not in Standby" (someone accidentally left controller switch in "Off/Reset" position and standby gen-set can not function during actual power failure. The control panel that houses the digital microprocessor and (8) point LED annunciator, will also have additional features: a magnetic circuit breaker (automatically trips open upon electric over-load); a three position control switch (test position for manual test operation; standby position for actual auto start-stop when power failure occurs; off/reset for repairs or for re-setting the controller after a fault is repaired; and a run time hour meter which totals run time for periodic service maintenance work. EXCEPTION TO THE USE OF STANDARD GILLETTE RECOMMENDED AUTO TRANSFER SWITCH The stand alone, SPS & SPH SERIES gen-set, with 2-wire start-stop control in the generator circuit, can be used with any brand or amp size, automatic transfer switch, with matching 2-wire control circuit. Following are reasons why a generator set only (without "packaged" auto transfer switch) is offered: 1. User wishes to install
larger amp size transfer switch to match utility distribution amp size.